JBS-100-A, A6 Single Entry Power Connection with Junction Box

November 2nd, 2010 · No Comments

The JBS-100-A is a NEMA 4X rated power connection kit. It is designed for use with Raychem® BTV-CR, BTV-CT, QTVR-CT, XTV-CT, KTV-CT and VPL-CT industrial parallel heating cables. The JBS-100-A6 utilizes larger terminal blocks to accommodate up to 6 AWG power wires.
This kit may be installed at temperatures as low as –40°F (–40°C). For easier installation store above freezing until just before installation. JBS-100-A, A6 Installation Instructions
1. • Allow approximately 24″ (60 cm) of heating cable for installation. For VPL, cut cable 12″ (30 cm) from bus indentation.
• Cut off heating cable end at about 45° for easier insertion. Indentation (bus wire connection on VPL heating cables only).
2. • Optional: If stand is to be installed on bottom side of pipe, knock out drain hole prior to inserting cable.
• With label on stand facing desired direction of box opening, push 18″ (45 cm) of heating cable through stand. Use cable lubricant if needed.
• Square off cable end with 90° cut.
3 • Lightly score outer jacket around and down as shown.
• Bend heating cable to break jacket at score, then peel off jacket.